TAIT & Associates
  • Engineering
    • Civil Engineering
    • Public Infrastructure
    • Land Surveying
  • Environmental
    • Fueling Systems
    • Consulting
    • Compliance
    • Training
  • Building
    • Architecture
    • Program Management
    • Construction Management
  • Land
    • Planning
    • Land Development
    • Entitlement
  • Our Story
    • About Us
    • Mission & Values
    • History & Timeline
    • Leadership
    • Social Responsibility
    • Company Culture
  • News
  • Locations
  • Login
    • TECS Online
    • FTP
  • Careers
TAIT & Associates
  • Our Story
    • About Us
    • Mission & Values
    • History & Timeline
    • Leadership
    • Social Responsibility
    • Company Culture
  • News
  • Locations
  • Login
    • TECS Online
    • FTP
  • Careers
  • Engineering
    • Civil Engineering
    • Public Infrastructure
    • Land Surveying
  • Environmental
    • Fueling Systems
    • Consulting
    • Compliance
    • Training
  • Building
    • Architecture
    • Program Management
    • Construction Management
  • Land
    • Planning
    • Land Development
    • Entitlement

Compliance

Helicopter Refueling
Our client operates helicopters for public safety. They were able to fuel the helicopters from the supplier located in the building next to their hanger. TAIT was asked to assist and expedite a fueling solution to help make helicopter refueling more efficient. The client got approval to put a 1,000 gallon Jet-A trailer on the apron at the hanger.
Oncor Electric
Dallas, Texas
TAIT was contracted by Oncor Electric, the electrical services supplier for northeast Texas, to remove a 12,000 gallon gasoline tank and product piping from their downtown maintenance facility in Dallas, Texas.  The site offered many challenges- the site is in a walled compound with low arched entrances and the tank was set between two canopies.  TAIT successfully removed the tank, performed soil sampling and provided a closure letter to the Texas Commission on Environmental Quality.  We were able to obtain site closure from the TCEQ.
Pacific Gas & Electric
Northern California
TAIT works closely with Pacific Gas & Electric (PG&E) in Northern California to keep their fueling systems up to date, and to make sure they meet all current regulations.  We perform UST removals, and AST installations at their facilities. These projects are Design/Build.  Our in-house team meets with PG&E staff to determine the needs for each facility, then we use the in-house Engineering Team to design the new systems, we permit the new installation, and then we construct the new Fueling system.
UST Designated Operator Services-Ongoing
Los Angeles, CA
TAIT was hired by the City of Los Angeles, Department of General Services to provide UST Designated Operator inspections and facility employee training for over 140 city sites. The sites include critical fire service, police, and other City service locations. In addition to the mandated Designated Operator monthly inspection, TAIT also conducts air quality inspections of the City’s fuel dispensing equipment.
Fleet Services Bureau Fuel Storage Tank Consulting and Construction Management-Ongoing
Long Beach, CA
TAIT hired by the Fleet Services Bureau of the City of Long Beach for underground storage tank (UST) consulting and construction management. The consulting role is centered on compliance with the consent judgment between the City of Long Beach and the state of California, while the construction management scope involves comprehensive management of all fuel storage tank capital improvement projects. The construction management role involves full service management. This includes development of project scope, review of bids, bid award selection input, facilitation of job-walks and kickoff meetings, and complete management of the construction activities (ensuring timeline adherence, change order processing, etc.).
Los Angeles World Airports Underground Storage Tank Inspection, Testing and Repair Services-Ongoing
Los Angeles, CA
TAIT was hired by the Los Angeles World Airports (LAWA) to provide underground storage tank inspection, testing, repair and alarm response services. In addition to routine inspection and testing services, TAIT has provided repair and upgrade services for some very unique airport fuel system challenges. Our team provided a temporary solar powered monitoring system for a fuel system in a remote location of the airport. Our experts also assisted the airport with repairs and system upgrades associated with the multi-billion dollar renovation of the LAX Tom Bradley International Terminal.
Environmental Due Diligence Review
TAIT’s environmental services include providing due diligence review for clients needing a second opinion on environmental issues of a project site. One good example of this type of service involved TAIT being contracted by a land developer to review the environmental issues at a former oil field in Southern California. The developer wanted a second opinion on whether the property could clear environmental hurdles for residential development. (more…)
TravelCenters Storm Water SWPPP
Ontario, CA
TAIT Environmental Services, Inc. prepared the storm water pollution prevention plan (SWPPP) for truck parking facilities as a requirement for the Industrial Storm Water Discharge Permit.  TAIT also performed employee training for monthly site inspections, and completed the storm water sampling from the outfalls at each site during the Qualifying Storm Events (QSEs).  TAIT’s Qualifi ed Industrial Storm Water Practitioners (QISPs) will assist the client with reporting and sampling requirements going forward.
Albertsons Hazardous Waste Management
Irvine, CA
A major grocery retailer contracted TAIT to assist in bringing their reverse logistics operations into compliance with California’s complex hazardous waste regulations. TAIT conducts on-going audits of the returned retail products at one of their Southern California Distribution Centers. TAIT’s trained hazardous waste technicians regularly conduct audits of the returned retail products, helping to classify products that are RCRA or California hazardous waste to ensure regulatory compliance.
Brea Transfer Station
Brea, California
During remedial excavation activities at the Brea Transfer Station, a deep zone of soil impacted by petroleum hydrocarbons was discovered in the southern part of the site.  TAIT subsequently assessed the extent of impacted soils, and utilized large-diameter auger borings to remove the impacted soil from the subsurface. TAIT met the client’s goal to remediate the site for future residential development, achieving site closure from the Orange County Health Care Agency.
California Administrative Office of the Courts
Various Locations, CA
The California Administrative Office of the Courts (AOC) is the staff agency of the Judicial Council, the policy-making body for the state court system. TAIT provides environmental compliance and construction support for AOC facilities throughout the state, including 58 Superior Court locations. Services include storage tank inspection, compliance testing, and construction. TAIT has also prepared Hazardous Materials Business Plans and Spill Prevention Control and Countermeasure (SPCC) Plans on behalf of AOC.
Major Telecommunications Company
Various Locations, TX
Worldwide, major telecommunications companies are supported by central offices, switches, and internet data centers throughout the United States. TAIT provides inspection, compliance testing, alarm response and repair services for critical backup power fuel systems at 200 plus locations throughout the Southwest.  
  • Tait Engineering
  • Civil Engineering
  • Public Infrastructure
  • Land Surveying
  • Tait Environmental
  • Fueling Systems
  • Consulting
  • Compliance Management
  • Training
  • Tait Building
  • Architecture
  • Program Management
  • Construction Management
  • Tait Land
  • Planning
  • Land Development
  • Entitlement
  • Our Story
  • Markets We Serve
  • Mission & Values
  • History & Timeline
  • Leadership
  • Social Responsibility
  • Locations
  • News
  • Housing Reports
  • Careers at TAIT
  • Available Positions
  • Contact Us
Main Office
701 N. Parkcenter Drive
Santa Ana, CA 92705
714-560-8200
General Inquiries
info@tait.com
Human Resources/Careers
careers@tait.com
Orange County Register - Top Workplaces 2022,2021,2020, 2019, 2018, 2017, 2016

© 2023 Tait and Associates, Inc. All Rights Reserved. Privacy Policy